-40%

WB D2 Wideband O2 Air Fuel Ratio Controller Gauge (Black-Red) No Sensor

$ 29.04

Availability: 147 in stock
  • Warranty: 90 Day
  • Manufacturer Part Number: WB_D2_BR
  • Item must be returned within: 30 Days
  • Restocking Fee: No
  • Country/Region of Manufacture: United States
  • Returns Accepted: Returns Accepted
  • Condition: New
  • Return shipping will be paid by: Buyer
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Brand: WB

    Description

    WB WIDEBAND
    WB D2 Wideband (Black - Red)
    Free Shipping
    WIDE-BAND.com since 2011
    WB D2 Digital Wideband O2 Air Fuel Ratio Controller 52mm (2") Gauge (Black-Red)
    - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
    Item Description:
    WB D2 LED Display color is RED
    Faceplates can be BLACK (default) or WHITE
    Item Specifications:
    D2 wideband controller gauge features:
    1 – Less wiring – controller on-board
    2 – Simple installation – plug-and-play
    3 – One of the five bright LED color options (Red / Green / Orange / Blue / White) per gauge for four configurable types of fuel (E85, Diesel, Gasoline and Methanol) and lambda display
    4 - Sweeping LED "needle" indicator from rich (green) then normal (orange) to lean (red)
    5 - Fail safe LOCKED connector - it is not possible to make a wrong connection
    6 - Anti-glare faceplate - Non-destructable polycarbonate. Additional faces are paid extra.
    7 - Multiple outputs for digital (to PC), analog (to data logger / EMS), narrowband for simulation and extra switch options
    8 - On-Gauge Programming Button - No need a PC or tablet for programming upper/lower limits and other settings
    OUTPUTS
    1 – Analog 0-5V (9=19 AFR) linear output for engine management systems (EMS) and data loggers (MegaSquirt)
    2 – Digital output is 9600 8N1 serial that can be connected to your PC
    3 – Simulated NB output
    WIRING
    WB D2 has a 4ft output cable (5 cables / green-white-red-brown-black)
    Red power cable goes to 12V source in your vehicle.
    Black cable goes to a grounded source such as battery ground (-) post.
    Green digital output is 9600 8N1 serial that can be connected to your PC.
    If you want to connect other devices such as data loggers or AFR gauges, you can use white analog cable for 0-5V output.
    Brown narrowband cable is for simulated NB.
    The sensor cable (8ft) should be routed in a way so that there would not be any contact with the exhaust piping and other extreme heat sources to prevent damage to the wiring.
    GUIDELINE FOR THE LOCATION OF THE OXYGEN SENSOR
    WIDEBAND O2 SENSOR IS NOT INCLUDED
    Weld the bung at least 24” downstream of exhaust port outlet or 24” after the turbocharger. It should always be before the Catalytic Converter. Also it should be before the X or H pipe if there is. Bung should be welded on the upper section which is located between 10AM or 2AM clock positions. Please check your vehicle for exhaust leaks, camshaft overlap and open exhausts because those would cause false lean readings. Not following these directions may result in premature failure of the sensor.
    In The Box:
    D2 gauge assembly, pre-assembled output and oxygen sensor cables with connectors.
    WIDEBAND O2 SENSOR IS NOT INCLUDED.
    Shipping
    Returns
    Disclaimer
    Shipping
    Returns
    Disclaimer
    We offer FREE shipping on all orders!
    Your order will be shipped within 2 working days of receiving payment (Monday-Friday) and you should expect to receive it two or five days after shipment.
    LIMITED WARRANTY
    APSX WIDEBAND warrants this product to be free from defects for 12 months from the date of purchase.
    Oxygen sensors are excluded from stated warranty.
    APSX WIDEBAND’s obligation under warranty shall be limited to repairing or replacing, under the discretion of APSX WIDEBAND, any part proven defective. This warranty is limited to the repair or replacement of parts in the manufactured good and the necessary labor done to affect its repair or replacement.
    SERVICE UNDER WARRANTY
    In the unlikely event that your APSX WIDEBAND hardware should fail during the warranty period, a Return Material Authorization number (RMA) must be first retrieved from APSX WIDEBAND. Support can be contacted through email: at wide-band.com. All serviceable goods must be packaged securely, RMA number, with all shipping charges prepaid and shipped to APSX WIDEBAND. Goods returned under warranty must be received by APSX WIDEBAND within ten (10) business days after the RMA number has been issued. Goods received after this period is subject to fees for the service of repair or replacement.
    CONDITIONS FOR WARRANTY VOID
    This warranty shall terminate and APSX WIDEBAND shall have no obligation pursuant to it if (1) your product has been modified or repaired in a manner not previously authorized by APSX WIDEBAND in writing,, (2) your product was subjected to accident, abuse, shipping damage, or improper use; (3) your product was not used or configured as specified in the this manual; or (4) your product was subjected to operating conditions more severe than those specified in the this manual.
    APSX WIDEBAND shall not be liable for direct, special, incidental, or consequential damages resulting from any legal theory including, but not limited to, lost profits, downtime, goodwill, damage, injury to persons, or replacement of equipment and property due to improper installation, integration and/or misuse of any APSX WIDEBAND’s product(s). This warranty applies to the original purchaser of product and is non-transferable. All implied warranties shall be limited in duration to the said 90 day warranty period.
    TERMS OF USE
    APSX WIDEBAND does not guarantee the product functionality with any ECU, data logger or other devices that uses the output signals. Implementation and integration of the product with any other device(s) must be done at your own risk. Improper installation and usage may lead to engine damage. Mount and install the product in a location where it does not obstruct the driver’s view and/or ability to safely control the vehicle.
    Click here to see description
    APSX WIDEBAND
    APSX D2 Wideband (Black - White)
    Free Shipping
    WIDE-BAND.com since 2011
    APSX D2 Digital Wideband O2 Air Fuel Ratio Controller Gauge Kit (Black-White)
    - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
    Item Description:
    APSX D2 LED Display colors available: WHITE (default), RED, BLUE, ORANGE and GREEN
    Faceplates can be BLACK (default) or WHITE
    IF THERE IS NO NOTE ON THE ORDER, IT WILL BE SHIPPED AS DEFAULT.
    Item Specifications:
    D2 wideband controller gauge features:
    1 – Less wiring – controller on-board
    2 – Simple installation – plug-and-play
    3 – One of the five bright LED color options (Red / Green / Orange / Blue / White) per gauge for four configurable types of fuel (E85, Diesel, Gasoline and Methanol) and lambda display
    4 - Sweeping LED "needle" indicator from rich (green) then normal (orange) to lean (red)
    5 - Fail safe LOCKED connector - it is not possible to make a wrong connection
    6 - Anti-glare faceplate - Non-destructable polycarbonate. Additional faces are paid extra.
    7 - Multiple outputs for digital (to PC), analog (to data logger / EMS), narrowband for simulation and extra switch options
    8 - On-Gauge Programming Button - No need a PC or tablet for programming upper/lower limits and other settings
    OUTPUTS
    1 – Analog 0-5V (9=19 AFR) linear output for engine management systems (EMS) and data loggers (MegaSquirt)
    2 – Digital output is 9600 8N1 serial that can be connected to your PC
    3 – Simulated NB output
    WIRING
    APSX D2 has a 4ft output cable (5 cables / green-white-red-brown-black)
    Red power cable goes to 12V source in your vehicle.
    Black cable goes to a grounded source such as battery ground (-) post.
    Green digital output is 9600 8N1 serial that can be connected to your PC.
    If you want to connect other devices such as data loggers or AFR gauges, you can use white analog cable for 0-5V output.
    Brown narrowband cable is for simulated NB.
    The sensor cable (8ft) should be routed in a way so that there would not be any contact with the exhaust piping and other extreme heat sources to prevent damage to the wiring.
    GUIDELINE FOR THE LOCATION OF THE OXYGEN SENSOR
    Weld the bung at least 24” downstream of exhaust port outlet or 24” after the turbocharger. It should always be before the Catalytic Converter. Also it should be before the X or H pipe if there is. Bung should be welded on the upper section which is located between 10AM or 2AM clock positions. Please check your vehicle for exhaust leaks, camshaft overlap and open exhausts because those would cause false lean readings. Not following these directions may result in premature failure of the sensor.
    In The Box:
    D2 gauge assembly, pre-assembled output and oxygen sensor cables with connectors and Bosch LSU4.2 (part# 17014). D2 assembly includes anti-glare faceplate, black bezel, bung and LED display.
    Shipping
    We offer FREE shipping on all orders!
    Your order will be shipped within 2 working days of receiving payment (Monday-Friday) and you should expect to receive it two or five days after shipment.
    Returns
    LIMITED WARRANTY
    APSX WIDEBAND warrants this product to be free from defects for 12 months from the date of purchase.
    Oxygen sensors are excluded from stated warranty.
    APSX WIDEBAND’s obligation under warranty shall be limited to repairing or replacing, under the discretion of APSX WIDEBAND, any part proven defective. This warranty is limited to the repair or replacement of parts in the manufactured good and the necessary labor done to affect its repair or replacement.
    SERVICE UNDER WARRANTY
    In the unlikely event that your APSX WIDEBAND hardware should fail during the warranty period, a Return Material Authorization number (RMA) must be first retrieved from APSX WIDEBAND. Support can be contacted through email: at wide-band.com. All serviceable goods must be packaged securely, RMA number, with all shipping charges prepaid and shipped to APSX WIDEBAND. Goods returned under warranty must be received by APSX WIDEBAND within ten (10) business days after the RMA number has been issued. Goods received after this period is subject to fees for the service of repair or replacement.
    CONDITIONS FOR WARRANTY VOID
    This warranty shall terminate and APSX WIDEBAND shall have no obligation pursuant to it if (1) your product has been modified or repaired in a manner not previously authorized by APSX WIDEBAND in writing,, (2) your product was subjected to accident, abuse, shipping damage, or improper use; (3) your product was not used or configured as specified in the this manual; or (4) your product was subjected to operating conditions more severe than those specified in the this manual.
    Disclaimer
    APSX WIDEBAND shall not be liable for direct, special, incidental, or consequential damages resulting from any legal theory including, but not limited to, lost profits, downtime, goodwill, damage, injury to persons, or replacement of equipment and property due to improper installation, integration and/or misuse of any APSX WIDEBAND’s product(s). This warranty applies to the original purchaser of product and is non-transferable. All implied warranties shall be limited in duration to the said 90 day warranty period.
    TERMS OF USE
    APSX WIDEBAND does not guarantee the product functionality with any ECU, data logger or other devices that uses the output signals. Implementation and integration of the product with any other device(s) must be done at your own risk. Improper installation and usage may lead to engine damage. Mount and install the product in a location where it does not obstruct the driver’s view and/or ability to safely control the vehicle.